Why Do Brick and Stone Surfaces Deteriorate?
Brick and stone faces can deteriorate through salt crystallisation, freezing of absorbed water, chemical attack or expansion of embedded materials or metal.
Understand how timber, masonry, concrete and steel behave in buildings, from load paths and connections to moisture, deterioration and durability.
15 articles
Brick and stone faces can deteriorate through salt crystallisation, freezing of absorbed water, chemical attack or expansion of embedded materials or metal.
Articulation joints accommodate movement of the supporting structure. Contraction joints open as masonry shortens. Expansion joints close as masonry grows or associated concrete shrinks. A joint can perform more than one of…
Joists carry the flooring and deliver loads to bearers or other supports. Bearers transfer those reactions to walls, posts or stumps and ultimately the foundations. The system relies on bearing, connections and restraint at each…
Mortar matters in a masonry appraisal because the units and their joints carry load, move and handle water as an assembly. A sound-looking pointing layer does not establish the condition of the bedding behind it. A hard…
Yes. Incompatible metals can accelerate corrosion where roof components touch and at downstream surfaces that receive runoff from a different metal. Identify the installed sheets, accessories and fasteners, then follow the water…
A house is designed for its permanent weight, loads from use and construction, environmental forces and movements such as shrinkage, thermal change and ground displacement.
Timber connectors corrode when their protection is inadequate for the water, salts, timber treatment or other conditions at the joint. Establish what the fitting connects and whether it carries a structural load before judging…
A timber roof carries loads to the building below through tied rafters, rafters supported on structural beams or engineered trusses. The outside shape does not establish which system is inside. Identify how the roof resists…
Wind exposure depends on what the airflow crosses before reaching a building, the height at which the speed is assessed, nearby qualifying shielding and the local landform.
Check roof trusses against their own design and layout because each truss is part of an engineered system with assigned loads, bearings, connections and bracing.
An attached awning needs its own wind assessment because the nearby building changes the airflow while the underside of the awning can still be exposed.
Timber shrinkage matters around brick veneer because the frame can shorten relative to a masonry leaf supported on its own base. A sill, door threshold or soffit carried by the frame can then move towards the brickwork and close…
Before cutting a chase, hole or recess in masonry, establish what the wall carries or restrains and locate the proposed cut relative to its supports, reinforcement, fixings and moisture details.
A specialist assessing suspected lightning damage needs evidence that connects the weather event to the actual equipment and its failure mechanism. Preserve the item and its history, obtain the complete lightning-location…
A membrane beneath a concrete slab limits moisture reaching the slab or flooring above. AS 2870:2011 distinguishes a vapour barrier from a more puncture-resistant damp-proofing membrane. Both depend on how the sheet is…