How do surroundings, height and hills affect wind exposure?

Wind exposure depends on what the airflow crosses before reaching a building, the height at which the speed is assessed, nearby qualifying shielding and the local landform. A building in the same wind region as its neighbour can still have a different site wind speed. Terrain, shielding and topography are separate influences and each needs to be considered for the wind approach in question.

A report may refer to all three in the same case. Terrain is the roughness of the wider upwind approach. Shielding assesses the effect of particular nearby buildings under stated conditions. Topography accounts for the effect of larger landforms such as hills, ridges and escarpments. A site can have rough terrain and no qualifying shielding, or sit near an exposed crest despite being within a developed suburb.

Terrain roughness and height describe the approaching airflow

Wind crossing open water or unobstructed land encounters different surface roughness from wind crossing closely spaced houses or a dense city centre. The roughness alters the wind speed profile with height. Thus a speed assessed for a low part of a building does not describe every exposed component higher up, and a building can project above obstructions relevant to a lower building nearby. Terrain in this context describes the airflow's approach, not the soil type on which the footing bears.

Airflow does not adjust instantly when terrain roughness changes. The historical procedure accounts for upwind lengths over different surfaces and the lag as wind adjusts. Houses around a development inland from an open foreshore do not erase that open approach. From the opposite direction, the wind may cross substantially more developed terrain. Check the relevant approach and height together.

Check whether the roughness-producing obstructions will persist during an event. In the historical procedure, vegetation in tropical cyclonic regions is not relied on to maintain terrain roughness. That is different from counting nearby buildings for shielding.

Shielding depends on the buildings in the relevant approach

Nearby buildings need not shield every side of a house. The historical AS/NZS 1170.2:2002 procedure as amended in 2005 uses a directional sector, distance and height criteria, with associated parameter conditions, to determine which buildings qualify. A low shed or isolated building outside the relevant approach does not automatically reduce the design speed. The historical method also identifies where shielding is not applied, including sufficiently steep average upwind ground.

A house may be sheltered near ground level in one sense because a neighbour interrupts the breeze, yet its upper parts can still be exposed under the design assessment. Compare the assessed height with the obstructions relied on and the orientation of the local walls. Do not use a single shielding description for all floors or all directions without checking its scope.

Landform can speed up wind even in a rougher area

On a hill or ridge, airflow approaching the rising ground can accelerate as it is forced over it. The effect described in the historical provisions depends on the height and shape of the landform, the slope upwind, the position relative to the crest and the height above ground. A street sloping along a ridge is not the same approach as one that brings wind up the face towards the crest. A property labelled hillside on a map may sit well away from the relevant local zone.

An escarpment and a rounded hill can produce different flow patterns. Steep slopes can create a separation zone, which is assessed separately under the historical method. A side that feels sheltered can still be governed by a higher speed. Use the historical lee-zone provision only for the geographic area it specifically covers, not for any site on the lee side of a hill.

What the assessment assumes about changing surroundings

Account for known changes to terrain and shielding in the design assumptions. Demolishing a nearby building may change shielding in one sector; a broad change in development density may affect the terrain classification. Check those influences separately. An added storey or rooftop plant can increase the relevant height without any change to the surroundings.

Give the assessor the building height and position, orientation, current and known proposed surroundings, and the position of any relevant slope or crest. Read the resulting assumptions against the part being designed. A low wall on one side and equipment high on the roof may have different governing cases. Where a neighbour or line of development is relied on, check which wind directions it affects and whether the assessment treats it as terrain, local shielding or neither.

For example, on removing a single nearby building in an otherwise developed district, check whether the shielding assessment changes without a substantial change to the roughness across the wider approach. Conversely, development farther upwind can change the character of the approach without providing a building close enough to count as local shielding.

The historical AS/NZS 1170.2:2002 procedure, as amended in 2005, illustrates the distinctions. Use the governing edition and design route to determine which information and values apply to the actual work.