What Does the Membrane Under a Concrete Slab Do?

A membrane beneath a concrete slab limits moisture reaching the slab or flooring above. AS 2870:2011 distinguishes a vapour barrier from a more puncture-resistant damp-proofing membrane. Both depend on how the sheet is installed. Neither can direct surface water away from a building or fix a plumbing leak.

Vapour and liquid water can reach a floor differently

Moisture can rise as vapour through air in the ground and be trapped beneath an impermeable floor covering. Liquid can also move by capillary action. Where salts are present and surfaces wet and dry, evaporation can leave salts behind and contribute to powdering or fretting of concrete or masonry and damage to floor coverings. The route matters because these conditions do not call for the same repair.

AS 2870:2011 Clause 5.3.3 specifies medium impact resistance for a vapour barrier and high impact resistance with additional resistance to puncture and penetration for a damp-proofing membrane. Reinforcement placement and concreting can damage film. Similar appearance or colour does not establish which level of performance the installed film provides.

Check the required moisture-control system against the provisions applicable to the project; a regional note in AS 2870:2011 does not establish current requirements. A vapour barrier is not a waterproof tank and does not replace suitable exterior levels or drainage.

The installation only works if the moisture path is interrupted

AS 2870:2011 Clause 5.3.3.4 addresses coverage beneath slabs and beams, sheet laps and continuity at plumbing penetrations. A gap around a service or a pulled-apart lap can bypass an otherwise intact sheet. The clause distinguishes the usual edge treatment from allowing a vapour barrier to terminate at the inside face of an external beam where justified by satisfactory local experience. Do not extend that allowance to a continuous damp-proofing system.

A minor puncture can have different consequences in a vapour barrier than in continuous damp-proofing for salt-damp conditions. The commentary to AS 2870:2011 calls for installation damage to a damp-proofing membrane to be repaired. That distinction does not remove Clause 5.3.3.4's requirements at pipe penetrations or establish that an unexamined tear is harmless. Identify the selected system and where it was damaged.

Product branding addresses what was supplied; a pre-pour inspection can address which parts were covered and whether pipes, corners and seams were continuous when viewed. A photo of intact film before reinforcement went in does not show whether subsequent work damaged it. Conversely, lack of a photograph at a junction does not prove the sheet was absent. Do not puncture the membrane or open a slab to try to inspect it as an owner.

Read the slab edge with the wall and exterior drainage

Where a masonry cavity meets a rebated slab edge, the rebate helps water drain out rather than into the building. The membrane under the slab, the cavity flashing and exterior ground levels perform different jobs at different locations. Check how they meet. A rebate alone does not establish the flashing, termite protection or waterproofing details.

Consider raised paving beside a house. Even if the sheet remains intact underneath, water can arrive from above through a slab-edge or wall junction where the exterior arrangement no longer works as intended. Conversely, a correctly graded surface does not establish that a concealed lap or pipe seal was retained during the pour. Finding the path matters because repairing a buried membrane, clearing a cavity drainage route and correcting external levels would address different problems.

Damp flooring does not locate a membrane defect

An impervious floor covering can make moisture at the slab surface apparent without telling you where that moisture originated. Compare the location of damage to outside edges and services, the time relationship to weather or plumbing work and when the slab was covered. Moisture still in the concrete and moisture entering later through the ground, from a leaking service or through the edge are distinct questions. A high reading at one point describes that location and test conditions; it does not show what route the moisture followed. A pattern concentrated alongside an exterior wall warrants a different first enquiry from one centred on a service route.

Ask the assessor which competing route the evidence supports before choosing a repair. An installation record can narrow the question without showing every concealed seam or proving how the membrane performs today. Check that any proposed work addresses the route identified: a new floor covering can alter where dampness becomes apparent without stopping moisture from reaching the slab. For an active water issue near electrical equipment or apparent loss of structural support, obtain the appropriate urgent professional, utility or emergency response before investigating finishes.